Immediately BioAerosol Monitoring System for Air

Estado de Disponibilidad:

Immediately BioAerosol Monitoring System for Air


Bioaerosol Monitoring System

BioAerosol Monitoring System (BAMS) is used for real-time environmental monitoring of microorganisms in the air.

Capacitive touch screen 8.0″

Portable 5.8Kg

Continuous monitoring 7*24hr

Mass storage 119G


PRODUCT FEATURES

Continuous Monitoring 24/7 continuous monitoring

lmmediate Data

Real-time data for both particlesand biological particles

People Oriented

Efficient user oriented design

Stable and reliable

First truly portable microbial monitoring device

Compliance with FDA21 CFR Part 11


Sampling Rule

Sampling rule consists of NORM mode and Custom mode. The NORM mode is used for the samplings per ISO/EUGMP/CHINESEGMP/Fed Std. Under this mode, parameters cannot be modified after the room and sampling scheme are selected (the background of sampling conditions turn to grey.) If the sampling process is stopped, the result of the standard report is invalid. The Custom mode is used for sampling for other purposes. Under this mode, sampling parameters such as location, volume, sample time can be modified and a sampling can be stopped at any moment.

Delay/Interval

In auto mode, the first sample of each location complies with the delay. The following samples comply with the interval. In the case of manual mode, all samples comply with the delay. The sampling can be stopped during delay and interval. Press the start icon again to continue the sampling. In the case of custom mode, delay and interval can be changed at any moment. The countdown mode is used for delay and interval.

Volume

This shows the current sampled volume (above the line) and total volume of the sample (below the line). In NORM mode, the volume cannot be changed.

Sample Time

This shows the current sampled time (above the line) and total time of the sample (below the line). In NORM mode, the sample time cannot be changed.


Anterior: 
Siguiente: 
CONTÁCTENOS
Realimentación
MicronView Limited se aprovecha de la óptica y la biotecnología para lograr un monitoreo de entorno estéril rápido y en tiempo real, proporcionando instrumentos de monitoreo avanzados y consumibles para entornos de producción y productos terminados en las industrias alimentaria, farmacéutica y cosmética.
Navegación rápida

Categoría de Productos

MicronView Limited

1-520-528-1882
mv@micronview.com
2300 Highway 365 Suite 110, Nederland Texas 77630,  USA.
Derechos de autor 2021 Micron View Limited. Todos los derechos reservados. Mapa del sitio| Con apoyo de Letrero