Laser Airborne Particle Counter for Compressed Air

Verfügbarkeitsstatus:

Laser Airborne Particle Counter for Compressed Air


Airborne Particle Counter (APC) is fully compliant with ISO14644-2015 and ISO21501-4 standard.

Capacitive touch screen8.0″

Zone20,000

Data 5 million sets

Portable 6.1Kg

Product details

Product Feature

8 inch capacitive touchscreen, quick response

Even with two pairs of latex gloves

Sealed 316L stainless steel enclosure and dust plug to prohibit dust and water

Automatically Collect Air Samples

APC data exceed the limit,triggers the BAS to start sampling

Operation Interface

Data

-Standard report: one key to generate ISO/EUGMPI CHINESEGMP reports

-Data review and data export

1. Sum up data by zone.

2.Freely switch counting unit between △/Σ/#,m /ft.

3.Automatically generate UCL values and average values

4.Search for sample records precisely by time,zone and operator.

-Data integrity: featured with audit trail.

Sampling

- Real-time concentration curves, to get a better understanding of environmental particle condition.

- Quick editing function, to make sampling more flexible.

Setup

- Clear layout for orders. Simple and easy to use.

- One-click for system software upgrade.

- Multiple sets of personalized sampling schemes

can be customized for any zone.


Description


Export zone information and sampling scheme as db files to USB flash drive, or import it from the USB flash drive to the device. When importing the exported db files to the device, the contents of zone information and sampling scheme in the file will overwrite the original content in the device.

Note: When the software version of the device changes, such as the Settings of the zone information and sampling scheme, it may cause import and export failures, or cause device crashes.



SPECIFICATIONS



FLOW RATE: A110: 100LPM±3%

A120: 50LPM±3%


A130: 28.3LPM±3%

SIZE RANGE: A110: 0.5µm-25µm

A120, A130: 0.3µm-25µm


SIZE CHANNELS: A110: 0.5µm, 1.0µm, 2.0µm, 3.0µm, 5.0µm, 10.0µm

A120, A130: 0.3µm, 0.5µm, 1.0µm, 3.0µm, 5.0µm, 10.0µm

SIZE RESOLUTION: <15% @ 0.5&micro;m (meets ISO 21501-4)

COUNT EFFICIENCY: A110: 50% &plusmn;20% for 0.5&micro;m, 100% &plusmn;10% for >0.75&micro;m (meets ISO 21501-4 and JIS B9921)

A120, A130: 50% &plusmn;20% for 0.3&micro;m, 100% &plusmn;10%for >0.45&micro;m (meets ISO 21501-4 and JIS B9921)

CONCENTRATION LIMIT: A110: 560,000 particles/ft&sup3;at 10% coincidence loss

A120: 840,000 particles/ft&sup3;at 10% coincidence loss

A130: 1,400,000 particles/ft&sup3;at 10% coincidence loss

ZERO COUNT: <1count/5min

EXHAUST: Internal HEPA filter (>99.997%@0.3&micro;m)

ZONE/ LOCATION: 20,000 rooms and 200,000 locations

SAMPLING TIME: 1 second to 168 hours

CYCLES: 1000 samples on one location

LASER SOURCE: Long life laser

DATA STORAGE: 3.5G, ≥5,000,000 sets of sample records

DISPLAY: 8” LCD capacitive touch screen

LANGUAGE: Chinese, English

DATA RELIABILITY: Compliant with 21 CFR Part 11

REPORTS: Compliant with ISO/EUGMP/CHINESEGMP/Fed Std

CALIBRATION FREQUENCY: Recommend at least once a year

DIMENSIONS (HXWXD): 254x204x263mm


1

1

Vorherige: 
Nächste: 
KONTAKTIERE UNS
Feedback
Micronview Limited nutzt die Optik und Biotechnologie, um eine schnelle, echtzeitige sterile Umweltüberwachung zu erreichen, indem sie fortgeschrittene Überwachungsinstrumente und Verbrauchsumgebungen für Produktionsumgebungen und Fertigerzeugnisse von Lebensmitteln, pharmazeutischen und kosmetischen Industrien versorgen.
Schnelle Navigation

Produkte Kategorie

Micronview Limited

1-520-528-1882.
mv@micronview.com
2300 Highway 365 Suite 110, Nederland Texas 77630, USA
Urheberrechte © 2021 Micron View Limited. Alle Rechte vorbehalten. Seitenverzeichnis| Unterstützung von Leadong