Sterile Airborne Particle Counter

Availability:

Sterile Airborne Particle Counter

Airborne Particle Counter (APC) is fully compliant with ISO14644-2015 and ISO21501-4 standard.

Capacitive touch screen8.0″

Zone20,000

Data 5 million sets

Portable 6.1Kg

Product details

Product Feature

8 inch capacitive touchscreen, quick response

Even with two pairs of latex gloves

Sealed 316L stainless steel enclosure and dust plug to prohibit dust and water

Automatically Collect Air Samples

APC data exceed the limit,triggers the BAS to start sampling

Operation Interface

Data

-Standard report: one key to generate ISO/EUGMPI CHINESEGMP reports

-Data review and data export

1. Sum up data by zone.

2.Freely switch counting unit between △/Σ/#,m /ft.

3.Automatically generate UCL values and average values

4.Search for sample records precisely by time,zone and operator.

-Data integrity: featured with audit trail.

Sampling

- Real-time concentration curves, to get a better understanding of environmental particle condition.

- Quick editing function, to make sampling more flexible.

Setup

- Clear layout for orders. Simple and easy to use.

- One-click for system software upgrade.

- Multiple sets of personalized sampling schemes

can be customized for any zone.



SPECIFICATIONS



FLOW RATE: A110: 100LPM±3%

A120: 50LPM±3%


A130: 28.3LPM±3%

SIZE RANGE: A110: 0.5µm-25µm

A120, A130: 0.3µm-25µm


SIZE CHANNELS: A110: 0.5µm, 1.0µm, 2.0µm, 3.0µm, 5.0µm, 10.0µm

A120, A130: 0.3µm, 0.5µm, 1.0µm, 3.0µm, 5.0µm, 10.0µm

SIZE RESOLUTION: <15% @ 0.5&micro;m (meets ISO 21501-4)

COUNT EFFICIENCY: A110: 50% &plusmn;20% for 0.5&micro;m, 100% &plusmn;10% for >0.75&micro;m (meets ISO 21501-4 and JIS B9921)

A120, A130: 50% &plusmn;20% for 0.3&micro;m, 100% &plusmn;10%for >0.45&micro;m (meets ISO 21501-4 and JIS B9921)

CONCENTRATION LIMIT: A110: 560,000 particles/ft&sup3;at 10% coincidence loss

A120: 840,000 particles/ft&sup3;at 10% coincidence loss

A130: 1,400,000 particles/ft&sup3;at 10% coincidence loss

ZERO COUNT: <1count/5min

EXHAUST: Internal HEPA filter (>99.997%@0.3&micro;m)

ZONE/ LOCATION: 20,000 rooms and 200,000 locations

SAMPLING TIME: 1 second to 168 hours

CYCLES: 1000 samples on one location

LASER SOURCE: Long life laser

DATA STORAGE: 3.5G, ≥5,000,000 sets of sample records

DISPLAY: 8” LCD capacitive touch screen

LANGUAGE: Chinese, English

DATA RELIABILITY: Compliant with 21 CFR Part 11

REPORTS: Compliant with ISO/EUGMP/CHINESEGMP/Fed Std

CALIBRATION FREQUENCY: Recommend at least once a year

DIMENSIONS (HXWXD): 254x204x263mm

WEIGHT: 6.1Kg (13.45lbs) (without battery)

ENCLOSURE: 316L Stainless Steel

POWER: AC 100-240V, 50 Hz/60 Hz

BATTERY: 10.8V, 9000mAh, rechargeable lithium battery

BATTERY ENDURANCE: A110: running for 4 hours

A120: running for 7 hours


A130: running for 9 hours

MAX POWER: consumption AC 90W

OPERATING CONDITIONS TEMPERATURE:: 5℃-35℃, relative humidity up to 95%

STORAGE CONDITIONS TEMPERATURE: -10℃-40℃, relative humidity up to 98%

SAFETY: EN 61010-1:2010, EN 61326-1:2013, EN 61326-2-2:2013,EN 60825-1:2014, EN 61000-6-1:2007, EN 61000-6-3:2007+A1,FCC Part 15, Subpart B

WARRANTY: 2 years after activation




Data

Title

Description


TouchMore functionicon to open the extended menu bar. The extended function includes Error RECs, FTP, Print Data, Export PDF, Export DATA and Delete Data. Touch the corresponding function icon to open the function interface.

Add comment function, touch this icon to add a comment to the sample data. After adding successfully, touchto view the history of comment. The displayed contents include the adding person, time, note content, and they are listed in reverse order according to the time of adding.


To review the list of error records. The errors consist of flow errors and laser errors. Touch any record to view all the content for that record. When there are more records than shown on the screen, touch the up arrow or down arrow to move up and down the screen.


Print the data, touch【OK】icon to preview the contents of the printout slip. Touch【】icon to print. During the process of printing, touch【】icon to stop printing. The data interface in a single room, touch【】icon to set the data ID that needs to be printed, enter “1-5” to print 5 slips which are ID: 1 to ID: 5, enter “1/5” to print out 2 slip which are ID:1 and ID:5.

After successfully connecting to FTP in the WIFI interface, enter the data interface to select the sample data to be transferred, enter the operator ID, and transfer the sample data file to the target folder via FTP.


Export PDF is used for exporting the sampling period records in the form of PDF file. It can be only exported to a MICRONVIEW USB flash drive. Multiple cycle data can be exported, or can only export one cycle data. When exporting one cycle data, the report title needs to be added. When no title is entered, the export report title defaults to the room name for that cycle. When exporting multiple cycles data, select ‘All in one file’ check box to combine the data into a single PDF file to export; or export to multiple PDF files in the form of one cycle data. One cycle data export report, including sampling data and location mean and statistics (mean, UCL values, SD values, maximum value and minimum value) of the room. Multiple cycles data export report only contains sample data.


Export data is used for exporting all of the data as db file, it can only be exported to a MICRONVIEW USB flash drive.


Delete】icon, touch it and the prompt “According to data management, all sample data of this device will be deleted” will pop up, touch【OK】icon to delete.


Search】icon, find the required records via search criteria such as Item number, start/end date, operator, group, zone, alarm and comment.


Returnicon, clear the current content.


To generate the standard report compliance with ISO, EUGMP, CHINESEGMP and Fed Std standard report. To analyze if the collected data comply with standard report requirements. Compliant results are judged as pass, otherwise fail. If the sampling condition does not meet the minimum requirements of the standard for the sampling condition, the result is invalid. Touch【】icon, Standards, Class, Status, Air Flow and Largest selected size can be re-selected. Allow to exclude one record. Touch【OK】icon to preview the standard report. Touch【】 icon to print the standard report.

ALL

Select “ALL” option on the data interface to export, FTP transfer or print all the data with one click. Deselect “ALL” option, all data is not selected.

Page

Select “Page” option on the data interface to export, FTP transfer or print all data on the current page. Deselect “Page” option, the current page data is not selected.



Previous: 
Next: 

PRODUCT CATEGORY

CONTACT US
Feedback
MicronView Limited takes advantage of optics and biotechnology to achieve fast, real-time sterile environment monitoring, by providing advanced monitoring instruments and consumable for production environments and finished products of food, pharmaceutical and cosmetic industries.
Quick Navigation

Products Category

Micronview Limited

  1-520-528-1882
 mv@micronview.com
  2300 Highway 365 Suite 110,  Nederland Texas 77627, USA
Copyright  2021 Micron View Limited.   All rights reserved.  Sitemap | Support By Leadong